Application:
General pupose capillary thermostats are widely used for maintaining the required temperature of an air or liquids in different kinds of electric appliances such as water heaters, boilers, washing machines, dryers, fan heaters, electric ovens and other kitchen equipment.
Design features:
Operation of capillary thermostats is based on liquids property to increase their volume when heated. A rise in temperature causes an expansion of the liquid inside a capillary and a bulb. It acts on a diaphragm installed in a thermostat housing and switches electrical contacts. This is how temperature regulation is performed inside the controllable device. Capillary thermostat does not consume electricity what makes it highly energy-efficient. Nominal contacts load is 16A at 250V AC. Sensing bulb and capillary tube can be made of stainless steel or copper depending on a model. There are two series of capillary thermostats produced by Essima - WKB and WKC with different design of the body. Operating temperature of our products ranges from 0°C to 350°C. Each item has a mounting bracket with two threaded holes M4 and center distance 28 mm. Models of Essima capillary thermostats and their characteristics are specified in a table below. Products with other characteristics are available on request.
General characteristics:
- Bulb and capillary material — copper or stainless steel.
- Contacts configuration — 1 normally closed (1NC) or 1 change-over (1CO) contacts.
- Operating temperature range: 0°С…+40°С, 0°С…+60°С, 30°С…+85°С, 30°С…+110°С, 0°С…+120°С, 50°С…+250°С, 50°С…+270°С, 50°С…+280°С, 50°С…+320°С, 50°С…+350°С.
- Electrical rating: 16A/250VAC.
- Mounting bracket center holes: 28 mm with M4 screw.
-
Model range and characteristics
-
Marking
-
Dimensions
Model |
Operating temperature, °C |
Hysteresis, °C |
Nominal contact load at 250V AC, A |
Capillary and bulb material |
Contacts configuration |
WKB-40S1 |
0...40 |
2...5 |
16 |
Stainless steel |
1 normally closed contact |
WKB-40S2 |
0...40 |
2...5 |
16 |
Stainless steel |
1 change-over contact |
WKB-60S1 |
0...60 |
4±2 |
16 |
Stainless steel |
1 normally closed contact |
WKB-60S2 |
0...60 |
4±2 |
16 |
Stainless steel |
1 change-over contact |
WKB-85S1 |
30...85 |
2...6 |
16 |
Stainless steel |
1 normally closed contact |
WKB-110S1 |
30...110 |
2...8 |
16 |
Stainless steel |
1 normally closed contact |
WKB-120S1 |
0...120 |
5±3 |
16 |
Stainless steel |
1 normally closed contact |
WKB-270S1 |
50...270 |
2...10 |
16 |
Stainless steel |
1 normally closed contact |
WKB-280S1 |
50...280 |
8±5 |
16 |
Stainless steel |
1 normally closed contact |
WKС-40С1 |
0...40 |
6±4 |
16 |
Copper |
1 normally closed contact |
WKС-90С2 |
30...90 |
5±3 |
16 |
Copper |
1 change-over contact |
WKС-120S2 |
30...120 |
6±3 |
16 |
Stainless steel |
1 change-over contact |
WKС-250S1 |
50...250 |
7±5 |
16 |
Stainless steel |
1 normally closed contact |
WKС-320S1 |
50...320 |
7±5 |
16 |
Stainless steel |
1 normally closed contact |
WKС-350S2 |
50...350 |
10±5 |
16 |
Stainless steel |
1 change-over contact |
WKС-350S1 |
0...350 |
8±5 |
16 |
Stainless steel |
1 normally closed contact |
WKB series with 1NC contact
Model
А, mm
B, mm
ØC, mm
L, mm
WKB-40S1
15
121
6
900
WKB-60S1
15
121
6
1000
WKB-85S1
15
75
6
1500
WKB-110S1
23
100
6
1200
WKB-120S1
15
85
6
2500
WKB-270S1
15
92
4
1500
WKB-280S1
23
153
3
900
WKB series with 1 change-over contact
Model
А, mm
B, mm
ØC, mm
L, mm
WKB-40S2
21
127
6
1000
WKB-60S2
21
127
6
1000
WKC series with 1NC contact
Model
А, mm
B, mm
ØC, mm
L, mm
WKС-40С1
15
112
6
900
WKС-250S1
15
160
3
2500
WKС-320S1
15
130
3
2500
WKС-350S1
20
90
3
900
WKC series with 1 change-over contact
Model
А, mm
B, mm
ØC, mm
L, mm
WKС-90С2
15
112
6
1000
WKС-120S2
15
80
6
1000
WKС-350S2
15
105
3
2500